Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Full dent. sci ; 1(2): 135-141, Aug. 15, 2010.
Article in Portuguese | LILACS, BBO | ID: lil-605596

ABSTRACT

Com o objetivo de desenvolver, caracterizar e avaliar uma superfície microtexturizada de implantes propôs-se a realização deste estudo primeiramente laboratorial, através da Microscopia Eletrônica de Varredura (MEV) e microanálise por Energia de Dispersão (EDS) e, em um segundo estágio in vivo em animais. Para isso, foram fornecidos pela empresa Implacil – Materiais Odontológicos (Implantes DeBortoli) 24 implantes cilíndricos, os quais foram divididos em dois grupos: 1 – Implantes jateados por TiO; 2 – Implantes jateados e microtexturizados por imersão em ácido Fluorídrico. Os resultados demonstraram que na primeira fase os implantes avaliados em MEV do grupo 2 tiveram uma morfologia superficial muito mais uniforme e regular que o grupo 1. Na análise por EDS também o grupo 2 apresentou um melhor resultado, não sendo identificado nenhum tipo de contaminante em suas amostras, diferentemente do grupo 1 o qual tivemos a presença de Alumínio. Na segunda fase em que foram utilizados seis coelhos, que receberam 2 implantes em cada tíbia, foi observado o índice de tecido ósseo corticalizado em contato com a superfície, após oito semanas, tivemos um índice médio de 37,10% no grupo 1 e 58,73% no grupo 2. Em conclusão podemos verificar que é possível controlar físico-quimicamente a microtexturização superficialdos implantes e que isso além de dar uma conformação mais uniforme a superfície, elimina a possibilidade de contaminantes, aumentando o índice de osteointegração e formação de tecido ósseo corticalizado.


In order to develop, characterize and to evaluate a microtextured surface implant proposed to achieve this first laboratory study by Scanning Electron Microscopy (SEM) and microanalysis by energy dispersion (EDS), and a second stage in vivo in animals. For this they were supplied by the company Implacil - Dental Materials (Implants Debortoli) 24 cylindrical implants, which were divided into two groups: 1 - Implants blasted by TiO, 2 - and microtextured blasted implants byimmersion in hydrofluoric acid. The results showed that the first phase the implants evaluated in the SEM group 2 had a surface morphology much more uniform and regular than group 1.The analysis by EDS also in group 2 was better, but no identification of any contaminant in their samples was found, in contrast to group 1 which had the presence of aluminum. In the second phase six rabbits were used receiving 2 implants in each tibia. It was observed the rate of bone corticalization in contact with the surface, after eight weeks, had an average rate of 37.10% in group 1 and 58 73% in group 2. In conclusion we can see that you can control the physical and chemical microtexturization of the surface of implants and that it gives a more uniform forming surface, eliminates the possibility of contaminants, increasing the rate of osseointegration andformation of bone cortical tissue.


Subject(s)
Animals , Dental Implantation, Endosseous , Dental Implants/methods , Dental Implants , Osseointegration/physiology , Titanium , Microscopy, Electron, Scanning/methods , Microscopy, Electron, Scanning , Data Interpretation, Statistical
3.
Rev. Asoc. Odontol. Argent ; 79(4): 225-30, oct.-dic. 1991. ilus
Article in Spanish | LILACS | ID: lil-115422

ABSTRACT

Se describen algunas soluciones quirurgicoprotésicas para casos con escaso hueso alveolar para recibir implantes oseointegrados. La instalación de implantes intencionalmente inclinados permite evitar la penetración en el seno maxilar. Se sugieren procedimientos de diagnóstico radiográfico para su precisa ubicación. Cuando el reborde alveolar es fino, es posible ensancharlo mediante la disyunción de las tablas y la colocación de un injerto óseo. El uso de la tomografía computada permite topografiar con precisión la trayectoria del conducto dentario inferior e instalar un implante pasando por su costado. El empleo de una buena plantilla quirúrgica resulta fundamental para la exactitud de la instalación


Subject(s)
Dental Implantation, Endosseous , Oral Surgical Procedures, Preprosthetic , Mouth Rehabilitation/methods , Alveolar Ridge Augmentation , Denture, Partial, Fixed
SELECTION OF CITATIONS
SEARCH DETAIL